Each MMIU can manage up to 16 electric meter, each of which requires a dedicated line to the MMIU and all of which have a shared earth connection
-
Support the use of infrared transmission for initialization and data reading
-
Each MMIU has the relay capability
-
Compact form of 173mm(L) x 120mm(W) x 60mm(D), easy to install into a meter box
-
Alternative of 3-phase and single-phase power supplies versions. The
3-phase power supply version is practically a redundancy power supply configuration to ensure that the MMIU can continue to operate as long as one of the phases is not disrupted in a power failure situation. The Data Concentrator Unit (DCU) had similar functions
-
Pulse signal is isolated by photo electricity to ensure reliable operation
-
Storage of data into nonvolatile RAM which does not need power supply to maintain memory
-
Low power consumption of below 0.1W on the average
-
Lead fused connection to be meter
-
Fire resistance and electric insulation of the casing measure up the national standards